A biventricular heart through the cardiac cycle

main.py runs one beat of a coarse biventricular mesh from the Rodero et al. (2021) virtual cohort, whose cavities are closed by valve plugs. Each ventricle is driven through the five phases of the cardiac cycle by pulse.cycle.CycleController:

  1. preload: a pressure ramp;

  2. isovolumic contraction: volume held at end-diastolic volume;

  3. ejection: a three-element Windkessel;

  4. isovolumic relaxation: volume held at end-systolic volume;

  5. filling: a prescribed inflow.

This is an open loop: unlike the closed loop, ejected blood leaves the model and filling is prescribed.

The run reproduces the em_tref7 run of the rodero_05 case in physcardems, Jenny Wang’s electromechanics stack, on simcardemsx and pulse. The module docstring of main.py lists the known differences from it.

The set-up

Running

The case data is not part of this repository. The example reads it from a checkout of physcardems, by default third-party/physcardems/cases/rodero_05.

cd examples/rodero_05
python3 main.py --t-end 20               # a quick check
python3 main.py                          # one beat, 800 ms; takes hours
python3 post.py --output-dir output
OptionMeaning
--case-dirThe physcardems case directory
--trefScale on Land’s reference tension of 120 kPa (default 7)
--t-endEnd time, in ms (default 800)
--output-dirWhere the results go (default output/)
--save-every, --save-every-ep, --checkpoint-every, --restart, --overwriteAs for the slab

Output

Besides the files every application writes, pv_loops.png and summary.json, the latter with the cycle’s phases and whether every step converged. post.py also writes tension statistics per cell type (active_stats.csv) and a pseudo-ECG (ecg.csv, ecg.png).

The run is not bit-reproducible across processes: compare runs to round-off.